However, many locks remain since they may effectively be providing transactionality in some operations (e.g. prim updates across multiple tables).
These are candidates for being replaced with proper database transactions, since this would not block unrelated operations (e.g. land save and object save)
or unrelated operations on the same tables (e.g. storage of one linkset whilst another is being removed).
In practice, any performance deg due to contention is probably rare and short lived as the major prim operations are performed in memory and only persisted some time afterwards.
These locks are not necessary since the connection is taken from the underlying mysql pool and not shared.
Such locking is already not done by some other parts of OpenSim.Data.MySQL.
Pointed out by arribasim-dev
This fixes http://opensimulator.org/mantis/view.php?id=7123
Users that use MySQL should change their MySQL configuration to support UTF8. In the config file /etc/my.cnf (Linux) or my.ini (Windows), add these settings:
[mysqld]
character-set-server=utf8
[client]
default-character-set=utf8
And then restart MySQL (on Linux: "sudo service mysqld restart").
Add new region crossing code to varregion
Conflicts:
OpenSim/Region/CoreModules/Framework/EntityTransfer/EntityTransferModule.cs
OpenSim/Region/Framework/Scenes/ScenePresence.cs
to denote terrain format revision.
Add terrain DB format revision codes to ISimulationDataStore.cs.
Setup so legacy compatible terrain storage and fetch is possible while
allowing future format extensions.
This requires a new GridService.GetDefaultHypergridRegions() so ROBUST services require updating but not simulators.
This method still returns regions flagged with just DefaultRegion after any DefaultHGRegions, so if no DefaultHGRegions are specified
then existing configured defaults will still work.
Immediate use is for conference where we need to be able to specify different defaults
However, this is also generally useful to send experienced HG users to one default location and local users whose specified region fails (e.g. no "home" or "last") to another.
This is in order to reduce the likelihood of naming clashes, make it easier to filter in/out attributes, ensure uniformity, etc.
All dynattrs in the opensim distro itself or likely future ones should be in the "OpenSim" namespace.
This does alter the underlying dynattrs data structure. All data in previous structures may not be available, though old structures should not cause errors.
This is done without notice since this feature has been explicitly labelled as experimental, subject to change and has not been in a release.
However, existing materials data is being preserved by moving it to the "Materials" store in the "OpenSim" namespace.